Duluth Heating and Cooling Guide: History of Heat Pumps

Monday, April 9th, 2012

Thermal energy is the natural movement from warm temperatures to colder temperatures creating energy in the change of temperature to the mass.  A heat pump typically is a device that moves the air (or other matter) in the opposite direction from its natural flow.

A heat pump often uses an intermediate fluid called a refrigerant which absorbs heat as it vaporizes and releases the heat when it is condensed,  using an evaporator to absorb the heat (or energy) from inside an occupied space and forcing this heat to the outside through the condenser. The key component that makes a heat pump different from an air conditioner is the reversing valve which allows for the flow direction of the refrigerant to be changed, allowing the heat to be pumped in either direction.

Timeless Technology

While mechanical movement of this energy, what we can actually call a pump,  has been a relatively recent invention,  the concept of this principal of physics has been in use since ancient times. Harnessing the power of geothermal energy (produced from the heat of the earth itself), natural hot springs “pumped” warm air into cool spaces in China and Europe thousands of years ago.

By 1852, Lord Kelvin had theorized the heat pump, but it took nearly 100 years to actually build one.  In the last half century, the technological advances have made heat pumps part of our lives in many ways.

First Pump

In the 1940s a man named Robert Webber was motivated to build the first known heat pump while tinkering with his refrigerator.  Accidently burning his hand on the outlet pipes of the cooling system, he was quite painfully awakened to an idea about the transference of heat.

Recognizing the freezer was constantly producing heat to cool its interior, he connected the outlet pipe to the storage tank of his hot water heater, extended that into a flow through pipes which heated air nearby, and  then used a fan to blow the warmth into another room.

The first heat pump was a crude, but effective method to provide comfort.  Creating a full-size version soon after, Wagner could heat his entire home.

Heat and Electricity

Today, Duluth heat pumps are built in many ways and shapes to heat or cool buildings of many sizes. As technological improvements are refined during this time of climate change and dwindling fossil fuels, heat pumps promise to play an important part in our futures.

For more information about any Duluth HVAC system, give Triad Mechanical a call today!

 

Value Care Club Package

Friday, March 30th, 2012

Triad Mechanical Air Conditioning and Heating Service of Lawrenceville, GA is pleased to present our new maintenance plan package that includes more than just a filter change. We understand the importance of maintaining HVAC systems per the manufacturer’s recommendations and would like the opportunity to provide you with that service. Please take a moment to review our Value Care Club Package. Give us a call today, or simply fill out our Contact Form online and we will get back to you shortly to take care of all your maintenance needs!

Atlanta Heat Pump FAQ: Why is Steam Rising from the Outdoor Unit of my Heat Pump?

Wednesday, March 21st, 2012

In the winter months, we often get calls from Atlanta customers about steam rising from the outdoor unit of their heat pumps, which is often mistaken for smoke. Steam rising from your outdoor unit is a normal during the heat pump defrost cycle. The defrost cycle prevents ice from accumulating on the outdoor coils.

Under normal conditions, your Atlanta heat pump should run without needing a defrost cycle. However, when temperatures drop near freezing, a sensor will set off the defrost cycle, during which the outdoor coils will heat up and melt any ice that has formed on the coils. During this cycle, you may see what can look like puffs of smoke, but it’s actually the steam caused by the coils melting the frost. The steam can appear to be denser if there’s excessive humidity or moisture in the air.

It is important to note that the defrost cycle should not last more than ten to fifteen minutes, and each cycle should only run every two hours or so. If you notice that the cycles last longer, run more often, or if you see ice on the outdoor coils of your heat pump after the cycle is finished, you may need a repair. Another concern is cooler temperatures in your home, which could indicate that the heat strips are not working properly during the defrost cycle.

Once the cycle is finished, the fan motor should come on again, but if it doesn’t come on several hours after the cycle, you should call us to send one a HVAC technicians to inspect your heat pump. There could be an issue with airflow, or a potential motor failure. When there’s a lack of adequate airflow, it can damage the compressor and other components. Call us any time you notice anything other than the normal steam rising from your heat pump during the winter.

There are some ways to prevent excess wear and tear on your heat pump during the winter. For instance, strong winds can greatly affect the performance of your heat pump and may cause abnormal defrost cycles. Make sure the outdoor components are protected from heavy wind by placing some type of natural or manufactured barrier around your heat pump, but be sure not to block the airflow. If you are buying a new heat pump, look for a model that has demand-defrost control. This feature helps to save energy by minimizing the defrost cycles.

Feel free to call Triad Mechanical if you have questions about your heat pump or Atlanta heating.

Winder HVAC Tip: Heat Pump Refrigerant Problems

Wednesday, February 29th, 2012

Your Winder home’s heat pump is a very complicated piece of equipment that uses a number of moving parts to compress and circulate refrigerant and extract heat from one environment and place it in another. So, if your heat pump has refrigeration problems, it will almost certainly cause problems for the heating or cooling of your home.

Common Refrigerant Problems

There are a number of potential problems your heat pump might face, especially as it begins to age and components become worn. Some common issues include:

  • Compressor Issues – The compressor is a component in your heat pump that compresses the refrigerant gas into a liquid. This liquid is what circulates through the device and extracts heat from the outside air (or inside your home when in cooling mode). If the heat pump doesn’t turn on properly, isn’t producing enough heat or is using a large amount of electricity suddenly, it may be a compressor problem.
  • Refrigerant Leaks – Your heat pump doesn’t consume any refrigerant during operation. So, if it starts to leak refrigerant, there is likely another problem and it should be repaired immediately (for health and environmental reasons). Common signs of a leak include suddenly higher electrical bills, inefficient heating and possibly even a faint odor near the device.
  • Freezing Up – If your heat pump freezes, you should check for any blocked air vents or registers, check the condensate line and check your filter for blockage. Most often, a freezing problem is directly related to something being clogged and is a relatively easy fix. The only way to know for sure is to call a professional to investigate, however.

A heat pump is a very complex piece of machinery with a number of moving parts that can all cause issues if not properly maintained. If your heat pump stops heating or cooling effectively and it is not a simple fix such as a filter or belt, you should call Triad Mechanical to inspect for more significant problems such as the compressor or refrigerant.

Berkeley Lake Heat Pump Repair Tip: Common Performance Problems

Friday, January 13th, 2012

The heat pump in your Berkeley Lake home needs to work year round to provide heat and air conditioning. This is why you want to make sure it’s performing as efficiently as possible to save on energy costs and prevent break downs. You should schedule an annual maintenance check-up and inspection with a certified HVAC technician to test the efficiency levels.

However, there are a few common causes of performance issues to be aware of so that you can be sure your heat pump performs at optimal levels. Call us if you have questions about heat pump performance issues, or to make an appointment for an annual inspection and professional cleaning.

Airflow Issues

There should always be a certain amount of airflow (measured in cubic feet per minute) in your heat pump to maintain proper efficiency levels. If the airflow is less than 350 cfm per ton, it could increase your energy costs. You should make sure your HVAC contractor checks the airflow whenever your heat pump is inspected. Always keep the coils clean. Sometimes the ducts are not the right size, or the fan speed needs to be increased, but often cleaning the coils will help airflow, which is why it is important to clean and maintain the components of your heat pump. A certified technician will know what methods are best, so if you suspect an airflow problem with your heat pump, call a professional heating technician.

Air Leaks in the Duct System

Inefficient or poorly-designed duct systems may not distribute air properly throughout your home because of potential air leaks. There should always be a balance between the intake and return air in a forced air system, which helps maintain a neutral pressure within the house and increase efficiency. Some contractors argue over how tightly a house should be sealed for this reason, but if your heat pump is losing heat through leaks in the air ducts, this will greatly affect its efficiency.

Improper Refrigerant

Refrigerant leaks are another common cause of low performance levels in heat pumps. Most heat pumps already have refrigerant when they leave the factory and shouldn’t have any issues. Heat pumps that are charged with refrigerant when they are installed can sometimes have the wrong amount of refrigerant. Either too much or too little refrigerant will lower the heat pump’s efficiency and performance levels. Always check the recommended refrigerant amount or ask an HVAC technician before you add refrigerant yourself.

If the heat pump in your Berkeley Lake home isn’t working properly, it is also affecting your heating bills. Call Triad Mechanical to set up an appointment.

Arcade Heat Pump Guide: The Defrost Cycle

Monday, January 9th, 2012

If your Arcade home has a heat pump, you’ll want to understand the defrost cycle to help you maintain your heat pump and troubleshoot repairs. While this is a basic guide, you should call a qualified HVAC technician if you experience major issues with your heat pump.

During the winter when a heat pump is heating your home, the cooler outdoor air that’s pumped in and heated may have excess moisture. The outdoor coil evaporates this moisture, but under certain weather conditions, frost can accumulate on the coil and decrease the overall efficiency of the heat pump.  To help reduce the potential for damage from the frost, heat pumps are manufactured with a defrost cycle to melt the frost from the outdoor coil. The defrost cycle occurs often during heavy frost conditions, so check weather reports if your defrost cycle seems to be running often.

At the beginning of the defrost cycle, the heat pump switches to the cooling mode and temporarily warms up the outdoor coil until it reaches somewhere around 60° F to melt the frost from the coil. To increase the temperature of the coil, the outdoor fan is prevented from turning on until the outdoor coil reaches the desired temperature. Weather conditions and the timing device both affect the amount of time it takes for the heat pump to move through the entire defrost cycle.

In older homes, electric heating elements are sometimes installed to prevent cool air from being distributed throughout the home. This element will turn on with the defrost cycle and shut down the blower fan inside the house. If you have an older heat pump, you may want to consider upgrading to a more efficient model.

Call Triad Mechanical any time if you have questions about the defrost cycle for the heat pump in your Arcade home.

How to Handle Your Finicky Talmo Heat Pump

Monday, December 12th, 2011

A heat pump is designed to keep your Talmo home comfortable. Warm weather, cold weather – it doesn’t matter. It should turn on when you need it and turn off when you don’t. So, when the device starts turning on and off without reason or when you need it to stay on, what exactly is the problem and how can you fix that problem without losing the heating or cooling capacity of your device.

Common Causes of the Problem

There are a number of reasons why your heat pump would turn off shortly after turning on, and most of the time this occurs in heating mode. If it occurs in cooling mode, you should have the device inspected immediately because there is likely something wrong with a core component like the compressor. For heating mode issues, here are some common problems:

  • Dirty Coils – If the coils are dirty, the device won’t be able to properly operate, especially if it has been some time since the last cleaning. Both sets of coils need to be cleaned at least once a year to avoid this becoming a problem.
  • Low Refrigerant Charge – If the refrigerant gets low, you’ll need to have it recharged because the pressure in the device will drop and it will therefore turn off after a few minutes of use.
  • Defrost Timer – If the defrost timer is forcing the device into a defrost cycle too often (usually it is set to 30, 60, or 90 minutes), the fan might turn off every few minutes after turning on. This is a common problem and is usually due to a thermostat or switch issue which can be fixed relatively easily.

Another thing to ask yourself when this problem occurs is whether the device is heating properly when on. Defrost timer issues don’t usually impinge on the heating ability of the device, while low refrigerant can. You want to make sure the device is working properly when on and not just cycling on and off without heating capacity.

Based on what you find, you’ll need a technician to take a closer look and ensure everything is working properly. Most repairs for this type of problem are relatively simple.

Heat Pump Blowing Cold Air? A Solution from a Commerce HVAC Contractor

Friday, December 9th, 2011

One of the most impressive things about a heat pump is that it can both cool and heat your Commerce home. But, if something goes wrong and your heat pump is suddenly trying to cool your home in the middle of the winter, you have a problem. Here are some possible causes of the issue and what you can do about them.

Defective Reversing Valve

The reversing valve is responsible for changing the flow of refrigerant between seasons so your heat pump can both heat and cool your home. So, if it breaks, you can imagine what happens next – you won’t switch into heating mode and your heat pump will try to air condition your home.

Defective reversing valves are hard to diagnose because the symptoms are largely the same as those of a defective compressor or condenser valve. However, because of how they are installed and where they are located, you will need a heating contractor to inspect this problem no matter what.

Low on Refrigerant

Your heat pump should never run low on refrigerant because it shouldn’t leak, but if it does and the refrigerant gets low or if your device is simply very old, this may be a problem. Low refrigerant means that the device cannot transfer enough heat between the outdoor air and the inside air and the air that gets blown through your ducts by the air handler isn’t heated as much as is necessary to warm your house.

The problem is relatively easy to fix, though you should also have your repairman check for leaks and a possible cause of the refrigerant being low in the first place.

Not Running at All

The final problem is one you should be able to notice quite easily. If the heat pump isn’t working at all but the air handler and blower are working fine, then the device will simply blow cold air from outside or possibly even just recycled cold air from inside. In either case, the heat pump isn’t running to heat the air and therefore, you’re getting whatever temperature it is outside.

This can be caused by a number of problems so it’s important to call for an HVAC contractor to inspect it immediately.

A Guide from Stone Mountain: How to Maintain High Efficiency Heat Pump Filters

Wednesday, December 7th, 2011

The filter on your heat pump is an integral part of your Stone Mountain home’s comfort system. Without that filter, the device will quickly be subjected to an influx of debris and contaminants that can get into the machinery and the air being filtered into your home. As a result, you need to make sure you properly maintain the filters to reduce stress on your heat pump.

Change Your Filters

High efficiency filters are designed to remove as much of the airborne contaminants in the air as possible. This is fantastic for keeping your indoor air clean. But if you don’t properly maintain the filter, air quality can worsen and your heat pump is put under unnecessary stress. Specifically, the extremely tight knit filter, designed to stop nearly anything from getting through, gets clogged.

Now your heat pump is forced to work much harder to draw the air it needs from outside and heat or cool your home. On top of that, the filter is filled with contaminants that can start to leak back into the air supply, actually making your indoor air quality worse than it would be otherwise. That’s why it is so important to clean your filters on a regular basis (for permanent filters) and replace them if they are one time use.

Recommended Filters

You have options as to which types of filters you use for your heat pump. Filters come in multiple options, from super high MERV rated filters that trap up to 99% of all contaminants as small as 0.3 microns.

Electrostatic filters are especially efficient because they extract contaminants of all types – from dust and mold to smoke and gas fumes. A good filtration system should effectively remove anything from the air without needing replacement too often.

Permanent filters tend to offer the best protection against airborne contaminants and generally need to be cleaned once a month. HEPA filters are often permanent and while each filter is different, these are often extremely effective at minimizing contaminants in the air without putting stress on your heat pump.

Troubleshooting Your Heat Pump Problems in Buckhead

Monday, December 5th, 2011

If your Buckhead home’s heat pump isn’t working properly, there are a number of things that might be wrong. But, where do you start and how do you solve these problems quickly and inexpensively? Here are some tips for common heat pump problems.

Low Air Flow

Your heat pump is designed to provide steady air flow to the entire house. When it was originally installed, the technician sized it to do so. If it suddenly stops providing enough air flow to your entire house or if the air flow it provides isn’t as comfortable as you’re used to, something is probably wrong.

More specifically, there is likely an issue with the heat pump itself since the device will compensate for most external problems by running longer and harder. A quick inspection will often rule out serious problems, so you should have someone inspect your device as soon as you notice a problem.

Leaky Duct

If there is an external problem, such as leaky ductwork, it tends not to be as noticeable right away. Often, when ducts are leaking, air flow problems will occur only in certain rooms of your home. Even then, the heat pump might be able to maintain the right temperature in those rooms – you’ll just have a higher energy bill because of the energy loss in the ductwork.

The best way to determine what is happening and how best to tackle the problem is to have someone test your ductwork for leaks, a relatively quick process.

High Energy Bill

If your energy bill suddenly increases dramatically, it is usually due to energy loss somewhere in the transfer between the heat pump and the rooms of your home. Leaky ducts can be the culprit, but so too can the air handler or the heat pump itself. If you notice a sudden increase in your energy bill, look for other symptoms like uneven heating or cooling in certain parts of your home or noises coming from the ductwork or your air handler.

No matter what other symptoms accompany the increase, you probably need repairs. Your home may still be comfortable now, but the heat pump can only make up for the problem for so long and in the interim, it is being put under excessive stress that reduces its lifespan.